2026-10-26
The H07RN-F 3G1.5 rubber-insulated flexible cable is a high-performance industrial line engineered for demanding conditions, where mechanical strength and environmental resistance are critical to system reliability. Its EPR insulation and sheath are intended to balance electrical performance with tolerance for harsh operating environments, making it a standard option in industrial automation and construction applications. The following assessment examines its technical specifications, installation boundaries and compliance profile.
The cable is rated at 450/750V and uses bare copper conductors with EPR rubber for both insulation and sheath. It is designed for a maximum conductor temperature of 90°C and a short-circuit temperature of 250°C, with a fixed-installation ambient range of -40°C to +50°C.
| Parameter | Specification |
|---|---|
| Rated voltage | 450/750V |
| Conductor material | Bare copper |
| Insulation and sheath material | EPR rubber |
| Maximum conductor temperature | 90°C |
| Maximum short-circuit temperature | 250°C |
| Fixed installation ambient temperature | -40°C to +50°C |
| CPR fire classification | Eca |
The cable is intended for medium-to-heavy mechanical loads in dry, wet and outdoor environments. Its EPR sheath provides resistance to oil, ozone and ultraviolet radiation, supporting stable performance on construction sites, in agricultural machinery and in cooling equipment.
Although the cable is highly adaptable, several boundary conditions apply during selection and installation:
The H07RN-F 3G1.5 complies with EN 50525-2-21, which covers general-purpose elastomer-insulated cables rated at 450/750V and below. For fire performance, it has passed the EN/IEC 60332-1-2 vertical flame propagation test, providing basic flame-retardant characteristics when a single cable burns. Its CPR reaction-to-fire class is Eca, in line with EU construction safety regulations.
When installed inside protected conduit or equipment, the cable's permissible voltage rating can rise to 1000V AC, allowing it to be used as a rotor connection cable for engines. During installation, the bending radius should be kept between four and eight times the cable's outer diameter (D) to avoid mechanical damage to the insulation.
The cable is also suitable for construction sites or agricultural workplaces that include flammable or explosive environments, provided the installation complies with applicable local explosion-proof electrical regulations.
Sorgularınızı doğrudan bize gönderin.